There were several issues with the socket state checking when the pipe
reader is not running:
- the number of object handles in the WaitForMultipleObjectsEx()
call might have been zero;
- a call to the waitForDisconnected(-1) might have hung;
- we did not perform a loop iteration for the waitFor...(0) calls,
so disconnect detection was unreliable.
These issues are related to the same code, so they don't seem to be
addressable separately.
Change-Id: I3bca872bb4191e6a7d38a693d81f7981af7fe145
Reviewed-by: Oswald Buddenhagen <oswald.buddenhagen@gmx.de>
|
||
|---|---|---|
| .. | ||
| auto | ||
| baselineserver | ||
| benchmarks | ||
| global | ||
| libfuzzer | ||
| manual | ||
| shared | ||
| testserver | ||
| CMakeLists.txt | ||
| README | ||
README
This directory contains autotests and benchmarks based on Qt Test. In order
to run the autotests reliably, you need to configure a desktop to match the
test environment that these tests are written for.
Linux X11:
* The user must be logged in to an active desktop; you can't run the
autotests without a valid DISPLAY that allows X11 connections.
* The tests are run against a KDE3 or KDE4 desktop.
* Window manager uses "click to focus", and not "focus follows mouse". Many
tests move the mouse cursor around and expect this to not affect focus
and activation.
* Disable "click to activate", i.e., when a window is opened, the window
manager should automatically activate it (give it input focus) and not
wait for the user to click the window.