Ivan Solovev ea1a6d3ae0 QLocale: add (in)equality operators with QLocale::Language
We do have an implicit constructor which allows construction of a
QLocale from the QLocale::Language enum values. It will be used when
doing the comparison.
However, do not rely on the implicit conversions, and provide the
operators that explicitly do the right thing. This also allows us to
save an extra allocation of QLocalePrivate.

Found in Qt 6.8 API review.

Amends 71bbc35a37.

As a drive-by: fix the order of the test slots in the unit test.

Change-Id: I37f8f5881469b7734705e06e471746814dd2ddf0
Reviewed-by: Edward Welbourne <edward.welbourne@qt.io>
Reviewed-by: Thiago Macieira <thiago.macieira@intel.com>
(cherry picked from commit 403b1abcad5f437c51dfabd7095b814e99e197a1)
Reviewed-by: Qt Cherry-pick Bot <cherrypick_bot@qt-project.org>
2024-09-04 08:37:48 +00:00
..
auto QLocale: add (in)equality operators with QLocale::Language 2024-09-04 08:37:48 +00:00
baseline CMake: Make baseline tests standalone projects 2024-07-03 11:42:45 +00:00
benchmarks fix: Redundant condition in abstractitemcontainer 2024-08-28 01:13:29 +00:00
global
libfuzzer Complete color space toICC write 2024-05-31 16:24:50 +02:00
manual Enable transparent windows with embeddedwindows example on Windows 2024-08-22 13:41:20 +00:00
shared Replace incorrect Metal config check in nativewindow.h 2024-05-01 14:24:06 +02:00
testserver Move shbang lines to before copyright headers 2024-05-23 23:58:10 +02:00
CMakeLists.txt Rid of 'special case' markers 2023-04-13 18:30:58 +02:00
README

README

This directory contains autotests and benchmarks based on Qt Test. In order
to run the autotests reliably, you need to configure a desktop to match the
test environment that these tests are written for.

Linux X11:

   * The user must be logged in to an active desktop; you can't run the
     autotests without a valid DISPLAY that allows X11 connections.

   * The tests are run against a KDE3 or KDE4 desktop.

   * Window manager uses "click to focus", and not "focus follows mouse". Many
     tests move the mouse cursor around and expect this to not affect focus
     and activation.

   * Disable "click to activate", i.e., when a window is opened, the window
     manager should automatically activate it (give it input focus) and not
     wait for the user to click the window.